Description

When signal pressure is applied to the switch valve in listed Chrysler transmissions, the valve is shuttled to the full stroke position. In this position, the release circuit to the torque converter is vented and the apply circuit is opened to the line pressure. This moves the torque converter from the released or fluid coupling state to the lockup state. The apply pressure on the torque converter is equal to the full line pressure.

Chipped and/or performance enhanced transmissions can reach line pressures of 250+ psi. This level of pressure can potentially deform or balloon the torque converter. This deformation can affect fluid performance, efficiency and durability. Along with this, bore wear at TCC switch valve allows critical fluid loss that prevents proper TCC operation.

Reconditioning the bore and installing Sonnax oversized TC apply limit switch valve kit 44912-41K limits the amount of pressure applied to the torque converter without affecting the line pressure and restores proper TCC operation.

  • Oversized valve protects the torque converter from ballooning and failure due to excess pressure
  • Carburized steel valve combats premature wear
  • Limits TC apply pressure to a max of 150 psi, even in chipped and high performance units

OEM calls this a TC switch valve. Sonnax is calling our version the TC apply limit switch valve because while it functions like the OE valve, it also limits the converter apply pressure.


You need this if:

  • Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.


Symptoms:

  • No lockup
  • TCC slip
  • TCC apply & release concerns
  • Damaged converter

Cause:

Chipped and/or performance enhanced transmissions can reach line pressures of 250+ psi. This level of pressure can potentially deform or balloon the torque converter. Bore wear at TC switch valve allows critical fluid loss that prevents proper TC operation.

Correction:

Reconditioning the bore and installing Sonnax oversized TC apply limit switch valve kit limits the amount of pressure applied to the torque converter without affecting the line pressure and restores proper TC operation.